Union Special BCE311P16 and BCE311UA26 economy bag closing machines
Mechanical and technical information for styles BCE311P16-1M, -1A, -1B, UA26-1M, BCE391P16-1M, from Union Special manual PT1604-GR: 40 topics on settings, threading, lubrication, maintenance and troubleshooting, each with the original manual pages.
Noise Emission
Equivalent continous A-weighted sound pressure level (LpAd) at the workstation: 78.5 dB(A) according to ISO 10821-C.6.3 at 2000 SPM and 50% duty cycle.
Safety Rules
1. Before putting the machine described in this manual into service, carefully read the instructions. The starting of each machine is only permitted after taking notice of the instructions and by qualified operators.
IMPORTANT! Before putting the machine into service, also read the safety rules and instructions from the motor supplier.
2. Observe the national safety rules valid for your country. The design of the machine is based on safety standards EN ISO 10821.
3. The sewing machine described in this instruction manual is prohibited from being put into service until it has been ascertained that the sewing units which these sewing machines will be built into, have conformed with the provisions of EC Machinery Directive 2006/42/EC, Annex II B.
The machine is only allowed to be used as foreseen.
The foreseen use of the particular machine is described in paragraph STYLE OF MACHINE of this instruction manual. Another use, going beyond the description, is not as foreseen.
4. All safety devices must be in position when the machine is ready for work or in operation. Operation of the machine without the appertaining safety devices is prohibited.
5. Wear safety glasses.
6. In case of machine conversions and all valid safety rules must be considered. Conversions and changes are made at your own risk.
7. The warning hints in the instructions are marked with one of these two symbols.
8. When doing the following the machine has to be disconnected from the power supply by turning off the main switch or by pulling out the main plug:
8.1 When threading needle(s), looper, spreader etc.
8.2 When replacing any parts such as needle(s), presser foot, throat plate, looper, spreader, feed dog, needle guard, folder, fabric guide etc.
8.3 When leaving the workplace and when the work place is unattended.
8.4 When maintaining the machine which has to be done regularly depending on the material being bagged (see also LUBRICATION).
8.5 When using clutch motors without actuation lock, wait until motor is stopped totally.
9. Maintenance, repair and conversion work (see item
8) must be done only by trained technicians or special skilled personnel under condsideration of the instructions. Only genuine spare parts approved by Union Special have to be used for repairs.
10. Any work on the electrical equipment must be done by an electrician or under direction and supervision of special skilled personnel.
11. Work on parts and equipment under electrical power is not permitted. Permissible exceptions are described in the applicable section of standard sheet EN 50110 / VDE 0105.
12. Before doing maintenance and repair work on the pneumatic equipment, the machine has to be disconnected from the compressed air supply. In case of existing residual air pressure after disconnecting from compressed air supply (e.g. pneumatic equipment with air tank), the pressure has to be removed by bleeding.
Exceptions are only allowed for adjusting work and function checks done by special skilled personnel.
CAUTION AREAS
Torque Requirements
Torque (measured in inch-pounds) is a "rotating" force in pounds applied through a distance by a lever (in inches or feet). This is accomplished by a wrench, screwdriver, etc. Many of these devices are available, which when set at the proper amount of torque will tighten the part to the correct amount and no tighter.
All straps and eccentric should be tightened to 26-28 inch pounds (3 - 3.2 Nm) unless otherwise noted.
Screws requiring a specific torque will be indicated on the illustrations.
Oil Specification Requirements
All oils shall be non compounded, straight mineral oils, of high viscosity index (will not thin down excessively with heat). Practically all oil companies have Union Special Specification 175 and their industrial representatives will make their recommendations conforming to Union Special requirements.
UNION SPECIAL SPEC. 175 (see page 87) Nominal Viscosity 100 S.S.U at 100°F (Nominally ISO Grade 22).
Viscosity at 100°F 90 - 125 S.U.S (22 cSt) Flash Point (min.) 350°F (176°C) Pour Point (max.) 20°F (- 7°C) Color (max). 1 Neutralization No. (max). 0.10 Viscosity Index (D&D min.) 90 Copper Corrosion (max.) 1 A Aniline Point 175-225°F (79-107°C) Compounding Not a requirement ASTM = American Society for Testing Materials NOTE: The use of non corrosive oxidation, rust and foam inhibitators and / or film strenght, and lubricity enhancers is permitted, but these additives must be completely soluble in the oil, they must not separate, nor be removed by wick feeding. „EP“ (extreme pressure), tackiness / adhesive, lead soap and detergent additives are not permitted, nor are solid lubricants like graphite, and PTFE, etc.
Putting Into Service
If applicable, compare the control voltage of the unit with the control voltage of the sewing head for start, stop and cutting. Check by turning the handwheel in operating direction if the machine works. A slight resistance will be felt as the feed dog rises. Check the threading of the machine.
Lubricate the machine as per oiling diagram.
Operating
Recheck threading of the machine.
For a neat closure the filled bag has to be prepared as follows: Spread the bag opening. Make sure that a safety distance between bag and feeding area (presser foot, feed dog, needle) of at least 100 mm (4") is kept to avoid serious injuries of fingers or hand.
Mounting the Proximity Switch for Feeler
Remove left end cover. Mount the electronic proximity switch (A) as shown in Fig. 1.
NOTE: Be careful when tightening the two screws (B) in order not to damage the proximity switch (A).
The electronic proximity switch (A) for styles BCE211P16-1M,
-1A, -1B is connected according to wiring diagram on page 27.
Needles
Each needle has both a type and a size number. The type number denotes the kind of shank, point, length, groove, finish and other details. The size number, stamped on the needle shank, denotes the largest diameter of the blade measured midway between the shank and the eye. Collectively, the type and size number represent the complete symbol which is given on the label of all needles packed and sold by Union Special.
Needle Ordering
When ordering needles use the complete type and size numbers as printed on the package to ensure prompt and accurate processing of your order. Acomplete order should read as follows: 100 needles, type 9848GF, size 250/100.
Threading the Machine
This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Inserting Needle
The standard needle is 9848GF 250/100. Insert needle according to the following procedure:
1. Bring needle head (A) to the highest position.
2. Loosen screw (B). Insert needle (C) into hole. The needle spot should face rearwards as viewed from the operator’s side, with the tapered flat of the needle shank facing screw (B).
3. Retighten screw (B).
Turn off main switch on machine before replacing the needle! Maschine aus!
Needle Thread Control
1. Needle thread lever to be set 1 1/8" (28mm) from the center of needle thread lever eyelet hole to the underside of the top needle thread strike-off support bracket.
2. The underside of "U" shaped needle thread control eyelet should be 1/4" (6.3mm) above the center line of the needle thread lever cross shaft.
3. Set eyelet that it is directly left of needle thread tension assembly to the bottom of its slot.
Looper Thread Control
1. Set the looper thread take-up lever to just contact the thread when the needle enters the throat plate.
2. The amount of strike off should be set so the thread just becomes tight as the looper reaches its furthest end of the travel.
Stitch Formation and Thread Tension
Set the needle thread tension to be light enough to maintain a needle loop at the tip of the needle on half the length of one stitch.
There should be approximately 9 ounces (2.5 N) of needle thread tension at the needle thread tension assembly and
2.5 ounces (0.7 N) of looper thread tension at the looper thread tension assembly.
Use just enough needle thread strike-off to be set with the „U“-shaped needle thread control eyelet to form an adequate needle loop.
STYLES BCE311P16-1M, UA26-1M:
Needle / Looper Synchronization Greifersynchronisierung
1. Synchronize with TT148 Synchronization Gauge Kit Remove the looper and insert the test pin (I) , 1/4" (6.3 mm) diameter x 1 3/4" (4.5 mm) long, in the looper holder and lock the rod when there is 1/4" protruding above the throat plate.
Position the needle at the bottom of its stroke.
Install the dial indicator (J) on the top of the machine. Set the indicator dial to zero when the looper holder is at the farthest right position.
Turn the handweel in the clockwise direction until the test pin (I) touches the throat plate. Record the number of revolutions and final indicator reading.
Turn the handwheel counterclockwise until the dial indicator reads “0” when the looper is again at right end of stroke.
Continue to turn the handwheel counterclockwise until the test pin (I) touches the throat plate again. Record the number of revolutions and final indicator reading.
The indicator must travel the same amount of revolutions in each direction. The final indicator reading must be within .008" (0.2 mm) of the first reading.
If the indicator does not return to zero, adjustment can be made by slightly turning belt sprocket at lower unit and lightly locking one of the screws (F). If there is a lower number reading of the indicator on looper front travel, turn slotted sprocket counterclockwise. If there is a lower number reading of the indicator at looper rear travel, turn slotted sprocket clockwise.
Tighten the three screws (F) to 100 in lb. (11.5 Nm) after adjustment is made.
2. Synchronize without TT148 Synchronization Gauge Kit If no indicator is available, set the synchronization measuring with a slide caliper or steel ruler.
Set the looper gauge to 13/54" (5mm).
Check the synchronization by moving the looper rearward behind the needle scarf. Continue moving the looper to the left so that the top of the needle eye (L) is flush with the bottom of the looper blade (K). Measure the distance from the looper tip to the left side of the needle (M).
Move the looper in the opposite direction to where the looper is in front of the needle. Set the top of the needle eye (L) flush with the looper blade (K), the same as above.
Measure the looper point to the left side of the needle. Both measurements should be the same within 1/64" (0.4mm) (M).
If the measurement with the looper in front of the needle is less than the rear, turn the slotted sprocket counterclockwise. If the measurement is less with the looper behind the scarf of the needle, turn the slotted sprocket clockwise.
Tighten the three screws (F) to 100 in lb (11.5 Nm).
Lubrication
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Changing Oil and Filters
This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Oil Flow Diagram
The oiling system consists of pressurized oil that is sent to strategic areas internally throughout the machine that require oil. First the oil travels from the oil chamber on the rear of the machine into the oil pump and then into the oil distributor (A) where it is sent to critical areas (B, C, D and E). There are 2 oil return lines (G and H) in the lower areas of the machine where the oil pump siphons oil through the filters (P) and then into the oil chamber.
Oil when flowing properly can be seen in the oil sight gauge. The oil level should be maintained between the 2 white lines in the oil chamber cover as seen in the oil sight gauge. The oil level should be checked after the machine has been running for several minutes. If a machine has been sitting out of operation for a period of time the oil may drain into the lower areas of the machine and will not be seen in the oil sight gauge, this is the reason for running the machine for several minutes before checking the level.
NOTE: This does not include the initial set up ot the machine as the oil is drained before shipment.
The oil filters can be accessed through the cover (C) on the back of the machine for inspection.
Oil is drained from the machine through the cover screw that is marked DRAIN (A). To make oil drain quicker loosen screw (B)
Maintenance Plan BCE300
This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Replacing the Scissors Type Thread Chain Cutter
The knives of the chain cutter can not be changed individually. The complete chain cutter part No. 10069C/10069D has to be replaced.
Remove left end cover, presser foot and throat plate. Turn pulley until the feed dog is in its front position. Loosen nut (O, Fig. 2) and screw (Z). Pull the thread chain cutter to the front and take it out of the machine.
Assemble the new thread chain cutter. Insert the slot on the rear knife pilot on the pin of the throat plate support. Tighten front knife with screw (Z) and lock with nut (O). Check if the cutting edges overlap approximately .012" (0.3 mm).
Remount throat plate, presser foot and left end cover.
Re-sharpening Thread Chain Cutter Knives
The knives of the chain cutter can be re-sharpened as long as the cutting edges will overlap approximately .012" (0.3 mm) and the knife pilot clears on the bottom surface of the throat plate when in cutting position. The knife pilot should not contact the bottom surface of the throat plate, because the stroke of the chain cutter must be limited by the nut (U, Fig. 2) striking against the hexagon head stop screw (V).
Adjusting the Stitch Length
Stitch length is set at the factory at 3SPI (9mm).
If adjustrment is necessary:
1. Remove the bracket and back right cover plate with their 4 screws (A).
2. Loosen stitch length adjusting screw stud (B)
3. Move adjusting screw stud (B) down to lengthen stitch length.
4. Move adjusting screw stud (B) up to shorten stitch length.
5. Tighten screw stud (B) to 40 in lbs (45 kg.cm)
6. After stitch length is changed, feed dog may need to be re-centered in the throat plate. If adjustment is necessary, loosen screw (C) and move feed dog as required, then tighten screw to 87 in lbs (100 kg/cm) NOTE: Needle guard requires no readjustment when stitch length is changed.
Turn off main power before setting stitch length! When using clutch motors without actuation lock wait until the motor has completely stopped.
Feed Dog Setting
Set the height of the feed dog in its highest position so that the rear teeth project .060" (1.5 mm) above the throat plate surface. Tilt front of the feed dog to be at its highest position when tilted, but not exceed .060" (1.5 mm).
Tilt to highest position.
Do not exceed .060" (1.5 mm)
Presser Foot and Chaining Section Pressu
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Looper Setting
Set the looper so that the looper point is .196" (5 mm) from the centerline of the needle, when the looper is at its furthest position to the right. Looper gauge number 21225-13/64 is available for setting the looper. The looper should pass as close as possible to the back of the needle without contacting .003" to .005" (0.08 to 0.13 mm) clearance. For adjustment, loosen screw in the looper holder, move forward or backward as required. Retighten screw in looper holder.
Needle Height Setting
1. Remove the BCE cover with its 3 screws. (A)
2. Remove the rubber plug and loosen screw (A). Set needle height by moving needle bar (B) up or down so that the top of the needle eye is flush with the bottom of the looper blade when looper point, in back of the needle, is .040" to .060" (1 to 1.5 mm) left to the left side of the needle (C). Tighten screw (A) securely, making sure scarf of needle is facing to the back.
Recheck looper setting.
Needle Guard Setting
1. Attach fixed rear needle guard to rubber seal frame
2. Rotate pulley in operating direction until the point of the looper is just entering the scarf of the needle.
Loosen screw A and move the needle guard B, to have .001" to .003" (0.025 to 0.08mm) clearance between the face of the needle guard and the back of the needle point.
Note: Needle guard will not need to be reset when stitch length is adjusted.
Feeler Setting
The feeler (C, D, Fig.1) should not have any lateral play but should turn readily. For this, adjust the centering shaft (E, Fig. 2) with centering screw (F) and lock nut (G) accordingly.
Loosen screw (H, Fig. 2) and center the feeler (C, D) in centering shaft (E) laterally. The feeler must turn readily. Retighten screw (H). Hang in tension spring (J, Fig. 1).
The feeler should be set at .256 - .290" (6.5 - 7.5 mm) (Fig. 1) between upper throat plate surface and upper edge of feeler at the bag entrance zone.
For adjustment loosen nut (K, Fig. 1) and turn-off screw (L), so that the head of screw does not contact the magnet in the magnet support stud. Loosen nut (M) and turn the feeler stop screw (N) in or out, as required, to adjust the correct feeler height. NOTE: When the presser foot rests on the throat plate (feed dog below throat plate), the clearance between upper edge of feeler and lower edge of the feeler slot cut-out in the presser foot (see Fig. 1) should be approximately .040" (1 mm).
Secure the set feeler height with lock nut (M, Fig. 1).
Switching Pressure Setting
The switching pressure on the feeler is set with screw (L, Fig. 1).
Turn screw (L) slowly towards the magnet in the magnet support stud until its head just contacts the magnet, then turn it back ¼ turn, so that the feeler moves freely and the screw head is within the range of influence of the magnet.
NOTE: The closer the head of screw (L, Fig. 1) to the magnet the higher the switching pressure on the feeler. Secure the position of screw (L) with lock nut (K).
Switching Point Setting
CAUTION! Adjustment has to be done without V-belt and without air pressure.
The electrical switching point of the proximity switch (A, Fig. 1) is determined by screw (Q, Fig. 1). The distance between screw head and the face of the proximity switch is approximately 5/64" (2 mm) (see Fig. 1), when the feeler is in home position. This distance 5/64" (2 mm) is not exactly the same for all switches. Connect the machine electrically. With feeler in home position set the proper switching point as follows:
Loosen nut (P, Fig. 1). Turn screw (Q) away from switch, until the switch switches on. Then turn screw (Q) slowly towards the switch, until the switch switches off. Now turn screw (Q) a further ½ turn towards the switch. Secure this position of screw (Q) with lock nut (P).
STYLES BCE311P16-1M, -1A AND -1B:
Scissors Type Thread Chain Cutter Setting
When the air cylinder for the chain cutter (R, Fig. 1) is not activated and the chain cutter (R) is in its home position below the throat plate, the knife tips of the chain cutter (R) should be positioned .020" (0.5 mm) below the throat plate top surface. To obtain this setting, adjust the knife drive lever (S, Fig. 2) and secure this position by tightening the two screws (T, Fig. 2). In cutting position, above the throat plate, the cutting edges of the chain cutter (R, Fig. 1) should overlap by .012" (0.3 mm) when nut (U, Fig. 2) on the piston rod of the air cylinder butts on the hexagon head stop screw (V).
For adjusting loosen lock nut (W, Fig. 2) and press nut (U) against the hexagon head stop screw (V). Now turn stop screw (V) in or out, as required, until the cutting edges overlap approximately .012" (0.3 mm). Secure the setting of stop screw (V) with lock nut (W).
NOTE: A. The piston of the air cylinder should not strike against the cylinder inside when actuated. The stroke of piston must be limited by nut (U) striking against hexagon head stop screw (V). Operating pressure of air cylinder: 3 to 4 bar (44 to 59 psi). B. The cylinder clevis must not hit the feeler return spring when actuated, adjust cylinder as needed.
Setting the Time Relays in the Switch Box of
THE SEWING STATION When the bag is closed the thread chain cutter should cut at the moment the sewing machine stops and the bag conveyed on just tightens the thread chain.
The time delay up to the cutting action is set on the time delay relay D1, the operating time of the solenoid valve is set on the impulse relay D2 and the time delay up to the stop of the motor is set on the time delay relais D3 in the switch box of the UNION SPECIAL sewing station 20600 div. BCE.
CAUTION! WHEN SETTING THE TIME RELAYS, THERE IS LINE-VOLTAGE ON THE OPEN SWITCH BOX.
D1
Adjustments Knife Alignment
With screws "C" just loose enough to move the knife holder, move the cylinder and align the moving knife holder prongs so they are in the lower knife guide area.
Tighten screws "C" and test the alignment, the prongs should align with no bind in the mechanism.
Height Adjustment
Loosen screws"A" just enough to move the mechanism up and down, then with the lower knife holder in its lowest position, set the moving knife "D" to overlap the stationary knife by 0.25mm to 0.50mm at point "B" Note: The knife alignment and height adjustment should be done simultaneously and each should be double checked once the screws are tightened to make sure nothing has moved or misaligned MAXIMUM PRESSURE 50 PSI (3.4 bar)
Setting the Time Relays in the Switch Box of
THE SEWING STATION.
When the bag is closed the tape cutter should cut at the moment the sewing machine stops and the bag conveyed on just tightens the tape.
The time delay for braking the motor up to the cutting action is set on the time delay relay D3 in the switch box of the UNION SPECIAL sewing station 20600 div. BC.
The switch box of the sewing stations includes an other time relay D5 in switching position 2 with turning knobs P1 and P2.
Because of the tape cutter design of this machine, the tape with thread chain is cut at the start and stop of the machine, to obtain equal projecting lengths of tape on both ends of the bag.
In switching position 1 only cutting of the trailing tape at the end of the bag is initiated.
Choose the time delay between the start of the sewing machine and the cutting of the tape on turning knob P1 of time relay D5 so that the projecting length of tape will be approx. 1 1/2" (35 mm).
The time delay up to the cutting action at the stop of the machine is set on the turning knob P2 of time delay relay D5. CAUTION! WHEN SETTING THE TIME RELAYS, THERE IS LINE-VOLTAGE ON THE OPEN SWITCH BOX.
D3
Wiring Diagram
This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Troubleshooting: problems, causes and solutions
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Identification of Machines
Each UNION SPECIAL BCE300 series machine is identified by a style number, which is stamped on the style plate located on the center portion at the rear of the casting. Serial number is also stamped.
STYLES OF MACHINES Medium speed and high performance automatic sewing machines with automatic start and stop of the machine and automatically operated thread chain or tape cutters for closing filled bags and sacks made of jute, cotton, paper, plastic or woven polypropylene tapes, bituminized or foil-laminated materials.
Equipped with guides for application of filler cord for sealing needle punctures.
The bag being fed into the machine starts the sewing operation by a feeler controlled, contactless, electronic proximity switch. When the bag is closed, the machine stops automatically . Thread chain respectivelly thread chain with binding tape are cut automatically. One needle, high throw, internal forced lubrication, with automobile type oil filter, totally enclosed plain feed mechanism, totally enclosed looper mechanism, stationary rear needle guard with no readjustment required when changing stitch length, and presser foot with independently spring-loaded chaining section.
BCE311P16-1M: Sewing machine for closing filled bags and sacks with a two thread double locked stitch.
With electro-pneumatically operated double acting cylinder thread chain cutter, operating pressure: 44 to 59 PSI (3 to 4 bar). Degree of protection of solenoid valve: IP65 (IEC 529).
Control Voltage: 24 V DC.
Seam Specification: 1.01.01/401 (ISO 4916/4915) 401 SSa-1 (ASTM Standard No. D6193 – USA) Stitch Range: 6 mm to 11.5 mm (2.2 to 4.2 SPI) Standard Setting: 9 mm (2.8 SPI) Capacity Under Presser Foot: 12.7 mm (1/2 inch) Sewing Capacity on Paper Bags: up to 32 plies, depending on weight of paper Working Diameters Hand Wheel: 108 mm (4 1/4 inch) Maximum Speed: up to 2000 stitches/min., depending on stitch length, speed of conveyor, type of operation, and material to be sewn.
Weight Net: 43 kg BCE311P16-1A: Same as BCE311P16-1M, but control voltage 200
- 230 V, 50/60 Hz.
BCE311P16-1B: Same as BCE311P16-1M, but control voltage 100
- 110 V, 50/60 Hz.
BCE391P16-1M: Same as BC311P16-1M but single thread seam specification 1.01.01/101(ISO 4916 and 4915) 101 SSa-1 (ASTMl Standard No. D6193 - USA) 10008A Blind Looper (extra send and charge item) will produce single thread chain stitch.
Stitch type: 101 (ISO 4915 / ASTMl Standard No. D6193 - USA). BCE311UA26-1M: Sewing machine for closing filled bags and sacks made of paper or plastic foil (minimum thickness of foil .007 in. (0.18 mm) with a two thread double locked stitch, and simultaneously binding the bag mouth of crepe paper or plastic tape. Presser foot accommodates easy open tapes.
For use with bag feed-in devices.
With electro-pneumatically operated guillotine-type thread chain and tape cutter, operating pressure: 44 to 59 PSI (3 to 4 bar). Degree of protection of solenoid valve: IP65 (IEC 529).
Control Voltage: 24 V DC.
Seam Specification: 3.01.01/401 (ISO 4916/4915) 401 BSa-1 (ASTM Standard No. D6193 – USA) Stitch Range: 6 mm to 11.5 mm (2.2 to 4.2 SPI) Standard Setting: 9 mm (2.8 SPI) Capacity Under Presser Foot: 12.7 mm (1/2 inch) Sewing Capacity on Paper Bags: up to 32 plies, depending on weight of paper Working Diameter of the Hand Wheel: 108 mm (4 1/4 inch) Maximum Speed: up to 2000 stitches/min., depending on stitch length, speed of conveyor, type of operation,andmaterialtobesewn.
Weight Net: 43 kg 10008A Blind Looper (extra send and charge item) will produce single thread chain stitch.
Stitch type: 101 (ISO 4915 / ASTM Standard No. D6193- USA).
Types of Bag Closures
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Types and Description
9848GF Round shank with tapered flat, square point, double groove spotted, chromium plated.
Sizes available: 200/080, 250/100, 300/120.
9848GFR Round shank with tapered flat, round point, double groove spotted.
Sizes available: 200/080, 250/100, 300/120.
For closing bags made out of paper it is recommended to use needle type 9848GF, for closing bags made of plastic or woven polypropylene fabric to use needle type 9848GFR.
The standard needle for this machine is 9848GF 250/100.
When changing the needle, make sure it is fully inserted in the needle head with the tapered flat of the needle shank facing the screw, before the screw is tightened.