Union Special UK
Menu
MachinesAll machinesInteractive parts manualsTechnical infoContact
Home › Mechanical & technical information › BCE311 NW economy bag closing machines

Union Special BCE311 NW economy bag closing machines

Mechanical and technical information for styles BCE311P01-1NW, P15-1NW, UA25-1NW, from Union Special manual PT1603-GR: 32 topics on settings, threading, lubrication, maintenance and troubleshooting, each with the original manual pages.

Safety first. Settings and repairs should be done by a trained mechanic, with the machine switched off and isolated from the electrical and compressed-air supply. Follow the safety rules in the manual. The original manual pages shown with each topic are the authority: text is shown only where it was checked word for word against them.
Safety

Noise Emission

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 7. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 7: Noise Emission
Manual page 7 — tap to enlarge

Safety Rules

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 8, 9. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 8: Safety Rules
Manual page 8 — tap to enlarge
Union Special manual PT1603-GR, page 9: Safety Rules
Manual page 9 — tap to enlarge
Technical data

Identification of Machine Styles

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 4, 5, 6. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 4: Identification of Machine Styles
Manual page 4 — tap to enlarge
Union Special manual PT1603-GR, page 5: Identification of Machine Styles
Manual page 5 — tap to enlarge
Union Special manual PT1603-GR, page 6: Identification of Machine Styles
Manual page 6 — tap to enlarge

Torque Requirements

Torque (measured in inch-pounds) is a "rotating" force in pounds applied through a distance by a lever (in inches or feet). This is accomplished by a wrench, screwdriver, etc. Many of these devices are available, which when set at the proper amount of torque will tighten the part to the correct amount and no tighter.

All straps and eccentric should be tightened to 26-28 inch pounds (3 - 3.2 Nm) unless otherwise noted.

Screws requiring a specific torque will be indicated on the illustrations.

From Union Special manual PT1603-GR, page 7. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 7: Torque Requirements
Manual page 7 — tap to enlarge

Oil Specification Requirements

All oils shall be non compounded, straight mineral oils, of high viscosity index (will not thin down excessively with heat). Practically all oil companies have Union Special Specification 175 and their industrial representatives will make their recommendations conforming to Union Special requirements.

UNION SPECIAL SPEC. 175 (see page 85) Nominal Viscosity 100 S.S.U at 100°F (Nominally ISO Grade

22).

Viscosity at 100°F 90 - 125 S.U.S (22 cSt) Flash Point (min.) 350°F (176°C) Pour Point (max.) 20°F (- 7°C) Color (max). 1 Neutralization No. (max). 0.10 Viscosity Index (D&D min.) 90 Copper Corrosion (max.) 1 A Aniline Point 175-225°F (79-107°C) Compounding Not a requirement ASTM = American Society for Testing Materials NOTE: The use of non corrosive oxidation, rust and foam inhibitators and / or film strenght, and lubricity enhancers is permitted, but these additives must be completely soluble in the oil, they must not separate, nor be removed by wick feeding. „EP“ (extreme pressure), tackiness / adhesive, lead soap and detergent additives are not permitted, nor are solid lubricants like graphite, and PTFE, etc.

From Union Special manual PT1603-GR, page 17. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 17: Oil Specification Requirements
Manual page 17 — tap to enlarge
Installation and operation

Putting Into Service

If applicable, compare the control voltage of the unit with the control voltage of the sewing head for start, stop and cutting. Check by turning the handwheel in operating direction if the machine works. A slight resistance will be felt as the feed dog rises. Check the threading of the machine.

Lubricate the machine as per oiling diagram.

From Union Special manual PT1603-GR, page 12. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 12: Putting Into Service
Manual page 12 — tap to enlarge

Operating

Recheck threading of the machine.

For a neat closure the filled bag has to be prepared as follows: Spread the bag opening. Make sure that a safety distance between bag and feeding area (presser foot, feed dog, needle) of at least 100 mm (4") is kept to avoid serious injuries of fingers or hand.

From Union Special manual PT1603-GR, page 12. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 12: Operating
Manual page 12 — tap to enlarge
Threading and needles

Needles

Each needle has both a type and a size number. The type number denotes the kind of shank, point, length, groove, finish and other details. The size number, stamped on the needle shank, denotes the largest diameter of the blade measured midway between the shank and the eye. Collectively, the type and size number represent the complete symbol which is given on the label of all needles packed and sold by Union Special.

From Union Special manual PT1603-GR, page 7. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 7: Needles
Manual page 7 — tap to enlarge

Needle Ordering

When ordering needles use the complete type and size numbers as printed on the package to ensure prompt and accurate processing of your order. A complete order should read as follows: 100 needles, type 9848GF, size 250/100.

From Union Special manual PT1603-GR, page 7. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 7: Needle Ordering
Manual page 7 — tap to enlarge

Threading the Machine

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 10, 11. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 10: Threading the Machine
Manual page 10 — tap to enlarge
Union Special manual PT1603-GR, page 11: Threading the Machine
Manual page 11 — tap to enlarge

Inserting the Needle

The standard needle is 9848GF 250/100. Insert needle according to the following procedure:

1. Bring needle head (A) to the highest position.

2. Loosen screw (B). Insert needle (C) into hole. The needle spot should face rearwards as viewed from the operator’s side, with the tapered flat of the needle shank facing screw (B).

3. Retighten screw (B).

Turn off main switch on machine before replacing the needle! Maschine aus!

From Union Special manual PT1603-GR, page 12. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 12: Inserting the Needle
Manual page 12 — tap to enlarge

Needle Thread Control

1. Needle thread lever to be set 1 1/8" (28mm) from the center of needle thread lever eyelet hole to the underside of the top needle thread strike-off support bracket.

2. The underside of "U" shaped needle thread control eyelet should be 1/4" (6.3mm) above the center line of the needle thread lever cross shaft.

3. Set eyelet that it is directly left of needle thread tension assembly to the bottom of its slot.

From Union Special manual PT1603-GR, page 23. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 23: Needle Thread Control
Manual page 23 — tap to enlarge

Looper Thread Control

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 24. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 24: Looper Thread Control
Manual page 24 — tap to enlarge

Stitch Formation and Thread Tension

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 25. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 25: Stitch Formation and Thread Tension
Manual page 25 — tap to enlarge

Needle / Looper Synchronization Greifersynchronisierung

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 28, 29. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 28: Needle / Looper Synchronization Greifersynchronisierung
Manual page 28 — tap to enlarge
Union Special manual PT1603-GR, page 29: Needle / Looper Synchronization Greifersynchronisierung
Manual page 29 — tap to enlarge
Lubrication and maintenance

Lubrication

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 13. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 13: Lubrication
Manual page 13 — tap to enlarge

Changing Oil and Filters

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 13, 14. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 13: Changing Oil and Filters
Manual page 13 — tap to enlarge
Union Special manual PT1603-GR, page 14: Changing Oil and Filters
Manual page 14 — tap to enlarge

Oil Flow Diagram

The oiling system consists of pressurized oil that is sent to strategic areas internally throughout the machine that require oil. First the oil travels from the oil chamber on the rear of the machine into the oil pump and then into the oil distributor (A) where it is sent to critical areas (B, C, D and E). There are 2 oil return lines (G and H) in the lower areas of the machine where the oil pump siphons oil through the filters (P) and then into the oil chamber.

Oil when flowing properly can be seen in the oil sight gauge. The oil level should be maintained between the 2 white lines in the oil chamber cover as seen in the oil sight gauge. The oil level should be checked after the machine has been running for several minutes. If a machine has been sitting out of operation for a period of time the oil may drain into the lower areas of the machine and will not be seen in the oil sight gauge, this is the reason for running the machine for several minutes before checking the level.

NOTE: This does not include the initial set up ot the machine as the oil is drained before shipment.

The oil filters can be accessed through the cover (C) on the back of the machine for inspection.

Oil is drained from the machine through the cover screw that is marked DRAIN (A). To make oil drain quicker loosen screw (B)

From Union Special manual PT1603-GR, pages 15, 16. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 15: Oil Flow Diagram
Manual page 15 — tap to enlarge
Union Special manual PT1603-GR, page 16: Oil Flow Diagram
Manual page 16 — tap to enlarge

Maintenance Plan BCE300

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 18, 19. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 18: Maintenance Plan BCE300
Manual page 18 — tap to enlarge
Union Special manual PT1603-GR, page 19: Maintenance Plan BCE300
Manual page 19 — tap to enlarge
Adjustments and settings

Adjusting the Stitch Length

Stitch length is set at the factory at 3SPI (9mm).

If adjustrment is necessary:

1. Remove the bracket and back right cover plate with their 4 screws (A).

2. Loosen stitch length adjusting screw stud (B)

3. Move adjusting screw stud (B) down to lengthen stitch length.

4. Move adjusting screw stud (B) up to shorten stitch length.

5. Tighten screw stud (B) to 40 in lbs (45 kg.cm)

6. After stitch length is changed, feed dog may need to be re-centered in the throat plate. If adjustment is necessary, loosen screw (C) and move feed dog as required, then tighten screw to 87 in lbs (100 kg/cm) NOTE: Needle guard requires no readjustment when stitch length is changed.

Turn off main power before setting stitch length! When using clutch motors without actuation lock wait until the motor has completely stopped.

From Union Special manual PT1603-GR, page 20. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 20: Adjusting the Stitch Length
Manual page 20 — tap to enlarge

Feed Dog Setting

Set the height of the feed dog in its highest position so that the rear teeth project .060" (1.5 mm) above the throat plate surface. Tilt front of the feed dog to be at its highest position when tilted, but not exceed .060" (1.5 mm).

Tilt to highest position.

Do not exceed .060" (1.5 mm)

From Union Special manual PT1603-GR, page 21. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 21: Feed Dog Setting
Manual page 21 — tap to enlarge

Presser Foot and Chaining Section Pressure

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 21. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 21: Presser Foot and Chaining Section Pressure
Manual page 21 — tap to enlarge

Looper Setting

Set the looper so that the looper point is .196" (5 mm) from the centerline of the needle, when the looper is at its furthest position to the right. Looper gauge number 21225-13/64 is available for setting the looper. The looper should pass as close as possible to the back of the needle without contacting .003" to .005" (0.08 to 0.13 mm) clearance. For adjustment, loosen screw in the looper holder, move forward or backward as required. Retighten screw in looper holder.

From Union Special manual PT1603-GR, page 22. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 22: Looper Setting
Manual page 22 — tap to enlarge

Needle Height Setting

1. Remove the BCE cover with its 3 screws. (A)

2. Remove the rubber plug and loosen screw (A). Set needle height by moving needle bar (B) up or down so that the top of the needle eye is flush with the bottom of the looper blade when looper point, in back of the needle, is .040" to .060" (1 to 1.5 mm) left to the left side of the needle (C). Tighten screw (A) securely, making sure scarf of needle is facing to the back.

Recheck looper setting.

From Union Special manual PT1603-GR, page 22. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 22: Needle Height Setting
Manual page 22 — tap to enlarge

Needle Guard Setting

1. Attach fixed rear needle guard to rubber seal frame.

2. Rotate pulley in operating direction until the point of the looper is just entering the scarf of the needle. Loosen screw A and move the needle guard B, to have .001" to .003" (0.025 to 0.08mm) clearance between the face of the needle guard and the back of the needle point.

NOTE: Needle guard will not need to be reset when stitch length is adjusted.

From Union Special manual PT1603-GR, page 23. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 23: Needle Guard Setting
Manual page 23 — tap to enlarge

Thread Chain Cutter Setting

The stationary knife is mounted to the throat plate. The moveable knife tip should be positioned so its cutting edge has a gap to the cutting edge of the stationary knife by .012" to .020" (0.3 to 0.5 mm) when in cutting position.

From Union Special manual PT1603-GR, page 25. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 25: Thread Chain Cutter Setting
Manual page 25 — tap to enlarge

Adjustments Knife Alignment

With screws "C" just loose enough to move the knife holder, move the cylinder and align the moving knife holder prongs so they are in the lower knife guide area.

Tighten screws "C" and test the alignment, the prongs should align with no bind in the mechanism.

From Union Special manual PT1603-GR, page 27. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 27: Adjustments Knife Alignment
Manual page 27 — tap to enlarge

Height Adjustment

Loosen screws"A" just enough to move the mechanism up and down, then with the lower knife holder in its lowest position, set the moving knife "D" to overlap the stationary knife by 0.25mm to 0.50mm at point "B" Note: The knife alignment and height adjustment should be done simultaneously and each should be double checked once the screws are tightened to make sure nothing has moved or misaligned MAXIMUM PRESSURE 50 PSI (3.4 bar)

From Union Special manual PT1603-GR, page 27. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 27: Height Adjustment
Manual page 27 — tap to enlarge
Troubleshooting

Troubleshooting: problems, causes and solutions

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 31. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 31: Troubleshooting: problems, causes and solutions
Manual page 31 — tap to enlarge
General information

Types of Bag Closures

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, page 6. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 6: Types of Bag Closures
Manual page 6 — tap to enlarge

Types and Description

9848GF Round shank with tapered flat, square point, double groove spotted, chromium plated.

Sizes available: 200/080, 250/100, 300/120.

9848GFR Round shank with tapered flat, round point, double groove spotted.

Sizes available: 200/080, 250/100, 300/120.

For closing bags made out of paper it is recommended to use needle type 9848GF, for closing bags made of plastic or woven polypropylene fabric to use needle type 9848GFR.

The standard needle for this machine is 9848GF 250/100.

When changing the needle, make sure it is fully inserted in the needle head with the tapered flat of the needle shank facing the screw, before the screw is tightened.

From Union Special manual PT1603-GR, page 7. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 7: Types and Description
Manual page 7 — tap to enlarge

Blank

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1603-GR, pages 26, 27. The manual pages show the figures and reference letters.
Union Special manual PT1603-GR, page 26: Blank
Manual page 26 — tap to enlarge
Union Special manual PT1603-GR, page 27: Blank
Manual page 27 — tap to enlarge
Need more help? Our technical team can advise on settings, parts and repairs. Call +44 (0)1706 871933 or send an enquiry.