Mechanical and technical information for styles BC211P16-1M, -1A, -1B, UA24-1M, UA26-1M, from Union Special manual PT1702-GR: 46 topics on settings, threading, lubrication, maintenance and troubleshooting, each with the original manual pages.

Safety first. Settings and repairs should be done by a trained mechanic, with the machine switched off and isolated from the electrical and compressed-air supply. Follow the safety rules in the manual. The original manual pages shown with each topic are the authority: text is shown only where it was checked word for word against them.
Safety

Noise Emission

Equivalent continous A-weighted sound pressure level (LpAd) at the workstation: 78.5 dB(A) according to ISO 10821-C.6.3 at 2700 SPM and 50% duty cycle.

From Union Special manual PT1702-GR, page 6. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 6: Noise Emission
Manual page 6 — tap to enlarge

Safety Rules

1. Before putting the machine described in this manual into service, carefully read the instructions. The starting of each machine is only permitted after taking notice of the instructions and by qualified operators.

IMPORTANT! Before putting the machine into service, also read the safety rules and instructions from the motor supplier.

2. Observe the national safety rules valid for your country. The design of the machine is based on safety standards EN ISO 10821.

3. The sewing machine described in this instruction manual is prohibited from being put into service until it has been ascertained that the sewing units which these sewing machines will be built into, have conformed with the provisions of EC Machinery Directive 2006/42/EC, Annex II B.

The machine is only allowed to be used as foreseen.

The foreseen use of the particular machine is described in paragraph STYLE OF MACHINE of this instruction manual. Another use, going beyond the description, is not as foreseen.

4. All safety devices must be in position when the machine is ready for work or in operation. Operation of the machine without the appertaining safety devices is prohibited.

5. Wear safety glasses.

6. In case of machine conversions and all valid safety rules must be considered. Conversions and changes are made at your own risk.

7. The warning hints in the instructions are marked with one of these two symbols.

8. When doing the following the machine has to be disconnected from the power supply by turning off the main switch or by pulling out the main plug:

8.1 When threading needle(s), looper, spreader etc.

8.2 When replacing any parts such as needle(s), presser foot, throat plate, looper, spreader, feed dog, needle guard, folder, fabric guide etc.

8.3 When leaving the workplace and when the work place is unattended.

8.4 When maintaining the machine which has to be done regularly depending on the material being bagged (see also LUBRICATION).

8.5 When using clutch motors without actuation lock, wait until motor is stopped totally.

9. Maintenance, repair and conversion work (see item

8) must be done only by trained technicians or special skilled personnel under condsideration of the instructions. Only genuine spare parts approved by Union Special have to be used for repairs.

10. Any work on the electrical equipment must be done by an electrician or under direction and supervision of special skilled personnel.

11. Work on parts and equipment under electrical power is not permitted. Permissible exceptions are described in the applicable section of standard sheet EN50110 / VDE 0105.

12. Before doing maintenance and repair work on the pneumatic equipment, the machine has to be disconnected from the compressed air supply. In case of existing residual air pressure after disconnecting from compressed air supply (e.g. pneumatic equipment with air tank), the pressure has to be removed by bleeding.

Exceptions are only allowed for adjusting work and function checks done by special skilled personnel.

From Union Special manual PT1702-GR, pages 8, 9. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 8: Safety Rules
Manual page 8 — tap to enlarge
Union Special manual PT1702-GR, page 9: Safety Rules
Manual page 9 — tap to enlarge
Technical data

Identification of Machines

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 4, 5. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 4: Identification of Machines
Manual page 4 — tap to enlarge
Union Special manual PT1702-GR, page 5: Identification of Machines
Manual page 5 — tap to enlarge

Torque Requirements

Torque (measured in inch-pounds) is a "rotating" force in pounds applied through a distance by a lever (in inches or feet). This is accomplished by a wrench, screwdriver, etc. Many of these devices are available, which when set at the proper amount of torque will tighten the part to the correct amount and no tighter.

All straps and eccentric should be tightened to 26-28 inch pounds (3 - 3.2 Nm) unless otherwise noted.

Screws requiring a specific torque will be indicated on the illustrations.

From Union Special manual PT1702-GR, page 6. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 6: Torque Requirements
Manual page 6 — tap to enlarge

Oil Specification Requirements

All oils shall be non compounded, straight mineral oils, of high viscosity index (will not thin down excessively with heat). Practically all oil companies have Union Special Specification 175 and their industrial representatives will make their recommendations conforming to Union Special requirements.

UNION SPECIAL SPEC. 175 (see page 85) Nominal Viscosity 100 S.S.U at 100°F (Nominally ISO Grade 22).

Viscosity at 100°F 90 - 125 S.U.S (22 cSt) Flash Point (min.) 350°F (176°C) Pour Point (max.) 20°F (- 7°C) Color (max). 1 Neutralization No. (max). 0.10 Viscosity Index (D&D min.) 90 Copper Corrosion (max.) 1 A Aniline Point 175-225°F (79-107°C) Compounding Not a requirement ASTM = American Society for Testing Materials NOTE: The use of non corrosive oxidation, rust and foam inhibitators and / or film strenght, and lubricity enhancers is permitted, but these additives must be completely soluble in the oil, they must not separate, nor be removed by wick feeding. „EP“ (extreme pressure), tackiness / adhesive, lead soap and detergent additives are not permitted, nor are solid lubricants like graphite, and PTFE, etc.

From Union Special manual PT1702-GR, page 13. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 13: Oil Specification Requirements
Manual page 13 — tap to enlarge
Installation and operation

Putting Into Service

If applicable, compare the control voltage of the unit with the control voltage of the sewing head for start, stop and cutting. Check by turning the handwheel in operating direction if the machine works. A slight resistance will be felt as the feed dog rises. Check the threading of the machine.

Lubricate the machine as per oiling diagram.

From Union Special manual PT1702-GR, page 12. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 12: Putting Into Service
Manual page 12 — tap to enlarge

Operating

Recheck threading of the machine.

For a neat closure the filled bag has to be prepared as follows: Spread the bag opening. Make sure that a safety distance between bag and feeding area (presser foot, feed dog, needle) of at least 100 mm (4") is kept to avoid serious injuries of fingers or hand.

From Union Special manual PT1702-GR, page 12. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 12: Operating
Manual page 12 — tap to enlarge

Mounting the Proximity Switch for Feeler

Remove left end cover. Mount the electronic proximity switch (A) as shown in Fig. 1.

NOTE: Be careful when tightening the two screws (B) in order not to damage the proximity switch (A).

The electronic proximity switch (A) for styles BC211P16-1M,

-1A, -1B is connected according to wiring diagram on page 28, for styles BC211UA24-1M according to wiring diagram on page 64, BC211UA26-1M according to wiring diagram on page 66.

From Union Special manual PT1702-GR, page 26. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 26: Mounting the Proximity Switch for Feeler
Manual page 26 — tap to enlarge
Threading and needles

Needles

Each needle has both a type and a size number. The type number denotes the kind of shank, point, length, groove, finish and other details. The size number, stamped on the needle shank, denotes the largest diameter of the blade measured midway between the shank and the eye. Collectively, the type and size number represent the complete symbol which is given on the label of all needles packed and sold by Union Special.

From Union Special manual PT1702-GR, page 6. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 6: Needles
Manual page 6 — tap to enlarge

Needle Ordering

When ordering needles use the complete type and size numbers as printed on the package to ensure prompt and accurate processing of your order. Acomplete order should read as follows: 100 needles, type 9848GF, size 250/100.

From Union Special manual PT1702-GR, page 6. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 6: Needle Ordering
Manual page 6 — tap to enlarge

Threading the Machine

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 10, 11. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 10: Threading the Machine
Manual page 10 — tap to enlarge
Union Special manual PT1702-GR, page 11: Threading the Machine
Manual page 11 — tap to enlarge

Inserting Needle

The standard needle is 9848GF 250/100. Insert needle according to the following procedure:

1. Bring needle head (A) to the highest position.

2. Loosen screw (B). Insert needle (C) into hole. The needle spot should face rearwards as viewed from the operator’s side, with the tapered flat of the needle shank facing screw (B).

3. Retighten screw (B).

Turn off main switch on machine before replacing the needle! Maschine aus!

From Union Special manual PT1702-GR, page 12. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 12: Inserting Needle
Manual page 12 — tap to enlarge

Needle Thread Control

1. Needle thread lever to be set 1 1/8" (28 mm) from the center of needle thread lever eyelet hole to the underside of the top needle thread strike-off support bracket.

2. The underside of “U” shaped needle thread control eyelet should be ¼” (6.3 mm) above the center line of the needle thread lever cross shaft.

3. Set eyelet that it is directly left of needle thread tension assembly to the bottom of its slot.

From Union Special manual PT1702-GR, page 23. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 23: Needle Thread Control
Manual page 23 — tap to enlarge

Looper Thread Control

1. Set the the looper thread take-up lever to just contact the thread when the needle enters the throat plate.

2. The amount of strike off should be set so the thread just becomes tight as the looper reaches its furthest end of the travel.

From Union Special manual PT1702-GR, page 24. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 24: Looper Thread Control
Manual page 24 — tap to enlarge

Stitch Formation and Thread Tension

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 25, 26. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 25: Stitch Formation and Thread Tension
Manual page 25 — tap to enlarge
Union Special manual PT1702-GR, page 26: Stitch Formation and Thread Tension
Manual page 26 — tap to enlarge

Needle / Looper Greifersynchronisierung

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 38, 39. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 38: Needle / Looper Greifersynchronisierung
Manual page 38 — tap to enlarge
Union Special manual PT1702-GR, page 39: Needle / Looper Greifersynchronisierung
Manual page 39 — tap to enlarge
Lubrication and maintenance

Lubrication

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 14, 15. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 14: Lubrication
Manual page 14 — tap to enlarge
Union Special manual PT1702-GR, page 15: Lubrication
Manual page 15 — tap to enlarge

Oil Flow Diagram

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 16, 17, 18, 19. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 16: Oil Flow Diagram
Manual page 16 — tap to enlarge
Union Special manual PT1702-GR, page 17: Oil Flow Diagram
Manual page 17 — tap to enlarge
Union Special manual PT1702-GR, page 18: Oil Flow Diagram
Manual page 18 — tap to enlarge
Union Special manual PT1702-GR, page 19: Oil Flow Diagram
Manual page 19 — tap to enlarge

Replacing the Scissors Type Thread Chain Cutter

The knives of the chain cutter can not be changed individually. The complete chain cutter part No. C10069B has to be replaced. Remove left end cover, presser foot and throat plate. Turn pulley until the feed dog is in its front position. Loosen nut (O, Fig. 2) and screw (Z). Pull the thread chain cutter to the front and take it out of the machine.

Assemble the new thread chain cutter. Insert the slot on the rear knife pilot on the pin of the throat plate support. Tighten front knife with screw (Z) and lock with nut (O). Check if the cutting edges overlap approximately .012" (0.3 mm).

Remount throat plate, presser foot and left end cover.

From Union Special manual PT1702-GR, page 28. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 28: Replacing the Scissors Type Thread Chain Cutter
Manual page 28 — tap to enlarge

Re-sharpening Thread Chain Cutter Knives

The knives of the chain cutter can be re-sharpened as long as the cutting edges will overlap approximately .012" (0.3 mm) and the knife pilot clears on the bottom surface of the throat plate when in cutting position. The knife pilot should not contact the bottom surface of the throat plate, because the stroke of the chain cutter must be limited by the nut (U, Fig. 2) striking against the hexagon head stop screw (V).

From Union Special manual PT1702-GR, page 28. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 28: Re-sharpening Thread Chain Cutter Knives
Manual page 28 — tap to enlarge

Replacing the Tape Cutter

Remove left end cover and solenoid impulse valve. Remove two mounting screws (L) and replace tape cutter.

Remount tape cutter with two mounting screws (L) so that lower knife edge is .020" (0.5 mm) below top of the throat plate.

Remount the parts removed.

CAUTION! Do not remove knife guard (M) while tape cutter is in operation!

From Union Special manual PT1702-GR, page 32. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 32: Replacing the Tape Cutter
Manual page 32 — tap to enlarge
Adjustments and settings

Adjusting the Stitch Length

1. Remove plug (A).

2. Turn handwheel until center adjustment screw B is located.

3. Turn adjustment screw B clockwise to lengthen stitch length.

4. Turn adjustment screw B counterclockwise to shorten stitch length.

5. Replace plug (A) after adjustment is made.

NOTE: Needle guard requires no readjustment when stitch length is changed.

Turn off main power before setting stitch length! When using clutch motors without actuation lock wait until the motor has completely stopped.

From Union Special manual PT1702-GR, page 20. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 20: Adjusting the Stitch Length
Manual page 20 — tap to enlarge

Feed Dog Setting

Set the height of the feed dog in its highest position so that the rear teeth project .060" (1.5 mm) above the throat plate surface. Tilt front of the feed dog to be at its highest position when tilted, but not exceed .060" (1.5 mm).

Tilt to highest position.

Do not exceed .060" (1.5 mm)

From Union Special manual PT1702-GR, page 21. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 21: Feed Dog Setting
Manual page 21 — tap to enlarge

Presser Foot and Chaining Section Pressu

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, page 21. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 21: Presser Foot and Chaining Section Pressu
Manual page 21 — tap to enlarge

Looper Setting

Set the looper so that the looper point is .196" (5 mm) from the centerline of the needle, when the looper is at its furthest position to the right. Looper gauge number 21225-13/64 is available for setting the looper. The looper should pass as close as possible to the back of the needle without contacting .003" to .005" (0.08 to 0.13 mm) clearance. For adjustment, loosen screw in the looper holder, move forward or backward as required. Retighten screw in looper holder.

From Union Special manual PT1702-GR, page 22. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 22: Looper Setting
Manual page 22 — tap to enlarge

Needle Height Setting

Remove the rubber plug and loosen screw (A). Set needle height by moving needle bar (B) up or down so that the top of the needle eye is flush with the bottom of the looper blade when looper point, in back of the needle, is .040" to .060" (1 to 1.5 mm) left to the left side of the needle (C). Tighten screw (A) securely, making sure scarf of needle is facing to the back. Recheck looper setting.

From Union Special manual PT1702-GR, page 22. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 22: Needle Height Setting
Manual page 22 — tap to enlarge

Needle Guard Setting

1. Slip shaft of guard onto holder.

2. Position the guard about central in the clearance of the rubber sealing frame.

3. Position the guard so the guard shank clears the right side of the needle. Allow .040" to .080" (1 to 2 mm) so if the largest diameter needle is ever used, it will clear.

4. Rotate adjustable pulley to bring the tip of the looper close to the right side of the needle, then push the guard to just contact the needle and not deflec it.Tighten the guard with one screw. Rotate adjustable pulley in direction of arrow to check this setting. If correct, tighten both screws very tight (will not have to be reset when changing stitch length).

From Union Special manual PT1702-GR, page 23. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 23: Needle Guard Setting
Manual page 23 — tap to enlarge

Feeler Setting

The feeler (C, D, Fig.1) should not have any lateral play but should turn readily. For this, adjust the centering shaft (E, Fig. 2) with centering screw (F) and lock nut (G) accordingly.

Loosen screw (H, Fig. 2) and center the feeler (C, D) in centering shaft (E) laterally. The feeler must turn readily. Retighten screw (H). Hang in tension spring (J, Fig. 1).

The feeler should be set at .236" (6.0 mm) (Fig. 1) between upper throat plate surface and upper edge of feeler at the bag entrance zone.

For adjustment loosen nut (K, Fig. 1) and turn-off screw (L), so that the head of screw does not contact the magnet in the magnet support stud. Loosen nut (M) and turn the feeler stop screw (N) in or out, as required, to adjust the correct feeler height. NOTE: When the presser foot rests on the throat plate (feed dog below throat plate), the clearance between upper edge of feeler and lower edge of the feeler slot cut-out in the presser foot (see Fig. 1) should be approximately .040" (1 mm).

Secure the set feeler height with lock nut (M, Fig. 1).

From Union Special manual PT1702-GR, page 26. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 26: Feeler Setting
Manual page 26 — tap to enlarge

Switching Pressure Setting

The switching pressure on the feeler is set with screw (L, Fig. 1).

Turn screw (L) slowly towards the magnet in the magnet support stud until its head just contacts the magnet, then turn it back ¼ turn, so that the feeler moves freely and the screw head is within the range of influence of the magnet.

NOTE: The closer the head of screw (L, Fig. 1) to the magnet the higher the switching pressure on the feeler. Secure the position of screw (L) with lock nut (K).

From Union Special manual PT1702-GR, page 26. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 26: Switching Pressure Setting
Manual page 26 — tap to enlarge

Switching Point Setting

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 26, 27, 28. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 26: Switching Point Setting
Manual page 26 — tap to enlarge
Union Special manual PT1702-GR, page 27: Switching Point Setting
Manual page 27 — tap to enlarge
Union Special manual PT1702-GR, page 28: Switching Point Setting
Manual page 28 — tap to enlarge

Scissors Type Thread Chain Cutter Setting

(REFER TO PAGE 25) When the air cylinder for the chain cutter (R, Fig. 1) is not activated and the chain cutter (R) is in its home position below the throat plate, the knife tips of the chain cutter (R) should be positioned .020" (0.5 mm) below the throat plate top surface. To obtain this setting, adjust the knife drive lever (S, Fig. 2) and secure this position by tightening the two screws (T, Fig. 2). In cutting position, above the throat plate, the cutting edges of the chain cutter (R, Fig. 1) should overlap by .012" (0.3 mm) when nut (U, Fig. 2) on the piston rod of the air cylinder butts on the hexagon head stop screw (V).

For adjusting loosen lock nut (W, Fig. 2) and press nut (U) against the hexagon head stop screw (V). Now turn stop screw (V) in or out, as required, until the cutting edges overlap approximately .012" (0.3 mm). Secure the setting of stop screw (V) with lock nut (W).

NOTE: A. The piston of the air cylinder should not strike against the cylinder inside when actuated. The stroke of piston must be limited by nut (U) striking against hexagon head stop screw (V). Operating pressure of air cylinder: 3 to 4 bar (44 to 59 psi). B. The cylinder clevis must not hit the feeler return spring when actuated, adjust cylinder as needed.

From Union Special manual PT1702-GR, page 28. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 28: Scissors Type Thread Chain Cutter Setting
Manual page 28 — tap to enlarge

Setting the Time Relays in the Switch Box of

THE SEWING STATION When the bag is closed the thread chain cutter should cut at the moment the sewing machine stops and the bag conveyed on just tightens the thread chain.

The time delay up to the cutting action is set on the time delay relay D1, the operating time of the solenoid valve is set on the impulse relay D2 and the time delay up to the stop of the motor is set on the time delay relais D3 in the switch box of the UNION SPECIAL sewing station 20600 div. BC.

CAUTION! WHEN SETTING THE TIME RELAYS, THERE IS LINE-VOLTAGE ON THE OPEN SWITCH BOX.

D1

From Union Special manual PT1702-GR, page 29. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 29: Setting the Time Relays in the Switch Box of
Manual page 29 — tap to enlarge

Tape Cutter Knife Adjustments

1. Install lower knife. Keep lock screws (A) on lower knife loose. Make sure lock screws do not protrude past knife surface to insure no interference.

2. Loosen lock screw (B). Set eccentric (C) to have movable knife overlap stationary knife by 1/32" (0.8 mm). Lock screws (B). Maintain movable knife in down position.

3. Loosen lock screw (D) and screw (E). Turn knife pressure screw (F) so movable knife has 40-50N (9-11 lbs.) force in and out. Make sure that screw (G) will not rotate.

Turning screw (F) clockwise increases pressure. Lock screw (G) again with screw (E) and retighten lock screw (D).

4. Turn screw (H) to slightly contact lower knife against movable knife.

5. Turn screw (I) to touch stationary knife slightly more than screw (H), and touch movable knife.

6. Turn screw (K) to slightly contact lower knife against movable knife. Lock screws (A). This determines the shear angle. Check shear angle by cutting the tape paper easily.

7. Repeat above procedure if knives are not cutting properly.

8. Lightly oil knife edges.

NOTE: Lightly apply grease to needle bearings and movable parts when shafts are removed for cleaning or replacement.

From Union Special manual PT1702-GR, page 31. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 31: Tape Cutter Knife Adjustments
Manual page 31 — tap to enlarge

Setting the Time Relays in the Switch Box of

THE SEWING STATION.

When the bag is closed the tape cutter should cut at the moment the sewing machine stops and the bag conveyed on just tightens the tape.

The time delay for braking the motor up to the cutting action is set on the time delay relay D3 in the switch box of the UNION SPECIAL sewing station 20600 div. BC.

The switch box of the sewing stations includes an other time relay D5 in switching position 2 with turning knobs P1 and P2.

Because of the tape cutter design of this machine, the tape with thread chain is cut at the start and stop of the machine, to obtain equal projecting lengths of tape on both ends of the bag.

In switching position 1 only cutting of the trailing tape at the end of the bag is initiated.

Choose the time delay between the start of the sewing machine and the cutting of the tape on turning knob P1 of time relay D5 so that the projecting length of tape will be approx. 1 1/2" (35 mm).

The time delay up to the cutting action at the stop of the machine is set on the turning knob P2 of time delay relay D5. CAUTION! WHEN SETTING THE TIME RELAYS, THERE IS LINE-VOLTAGE ON THE OPEN SWITCH BOX.

D3

From Union Special manual PT1702-GR, page 33. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 33: Setting the Time Relays in the Switch Box of
Manual page 33 — tap to enlarge

Time Relays

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 33, 34. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 33: Time Relays
Manual page 33 — tap to enlarge
Union Special manual PT1702-GR, page 34: Time Relays
Manual page 34 — tap to enlarge

Adjustments Knife Alignment

With screws "C" just loose enough to move the knife holder, move the cylinder and align the moving knife holder prongs so they are in the lower knife guide area.

Tighten screws "C" and test the alignment, the prongs should align with no bind in the mechanism.

From Union Special manual PT1702-GR, page 34. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 34: Adjustments Knife Alignment
Manual page 34 — tap to enlarge

Height Adjustment

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 34, 35. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 34: Height Adjustment
Manual page 34 — tap to enlarge
Union Special manual PT1702-GR, page 35: Height Adjustment
Manual page 35 — tap to enlarge

Adjustments Slide Block/guide Setting

The knife guide should be adjusted in the slide block to have a minimal to no shake and still be free. This is adjusted by using the 3 adjusters "E" on the slide block. Remove the rubber cap and loosen the nut. On the inside of the nut is a set screw. Using a 1.5mm allen carefully turn the screw clockwise to remove shake. On the body near each adjuster it is marked as to which area is being adjusted.

From Union Special manual PT1702-GR, page 35. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 35: Adjustments Slide Block/guide Setting
Manual page 35 — tap to enlarge

Knife Alignment

With screws "B" just loosen enough to move the knife holder, rotate the cylinder and align the moving knife holder prongs so they are in the lower knife guide area at the bottom of the stroke. Tighten screws "B" and test alignment, the prongs should align with no bind in the mechanism.

From Union Special manual PT1702-GR, page 35. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 35: Knife Alignment
Manual page 35 — tap to enlarge

Height Adjustment

Loosen screws "A" just enough to move the mechanism up and down, then with the lower knife holder in its lowest position set the moving knife "D" to overlap the stationary knife by 0.25mm to 0.50mm.

Note: The knife alignment and height adjustment should be done simultaneously and each should be double checked once the screws are tightened to make sure nothing has moved or misaligned.

MAXIMUM PRESSURE 55 PSI (3.8 bar)

From Union Special manual PT1702-GR, page 35. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 35: Height Adjustment
Manual page 35 — tap to enlarge

Adjusting the Clearance on C29476GC5

This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, pages 36, 37. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 36: Adjusting the Clearance on C29476GC5
Manual page 36 — tap to enlarge
Union Special manual PT1702-GR, page 37: Adjusting the Clearance on C29476GC5
Manual page 37 — tap to enlarge
Electrical and pneumatic

Wiring Diagram

STYLES BC211P16-1M, -1A, -1B Pay attention to the numbers on contact insert of plug when connecting the cable leads.

When assembling the plug choose builtin position “A” for the contact insert, i.e.

screw driver slot, ground contact and the letter “A” on the contact insert must point to the wide stay on the plug housing after being pushed in and locked (see illustration).

STYLES BC211T11-1

From Union Special manual PT1702-GR, pages 30, 31. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 30: Wiring Diagram
Manual page 30 — tap to enlarge
Union Special manual PT1702-GR, page 31: Wiring Diagram
Manual page 31 — tap to enlarge
Troubleshooting

Troubleshooting: problems, causes and solutions

This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).

From Union Special manual PT1702-GR, page 40. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 40: Troubleshooting: problems, causes and solutions
Manual page 40 — tap to enlarge
General information

Types of Bag Closures

Fold over closure manually by operator or by additional bag feed-in device with bagtop fold-over device.

BC211P16-1M, 16-1A, 16-1B, BC291P16-1M BC211U24-1M, UA24-1M, UA26-1M,T11-1

From Union Special manual PT1702-GR, page 5. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 5: Types of Bag Closures
Manual page 5 — tap to enlarge

Types and Description

9848GF Round shank with tapered flat, square point, double groove spotted, chromium plated.

Sizes available: 200/080, 250/100, 300/120.

9848GFR Round shank with tapered flat, round point, double groove spotted.

Sizes available: 200/080, 250/100, 300/120.

For closing bags made out of paper it is recommended to use needle type 9848GF, for closing bags made of plastic or woven polypropylene fabric to use needle type 9848GFR.

The standard needle for this machine is 9848GF 250/100.

When changing the needle, make sure it is fully inserted in the needle head with the tapered flat of the needle shank facing the screw, before the screw is tightened.

From Union Special manual PT1702-GR, page 6. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 6: Types and Description
Manual page 6 — tap to enlarge

Optional Tape Folder for BC211T11-1 & Ua

STYLES The folder has to be aligned with the support rods to the top surface of throat plate. The height should be adjusted so, that the tape fully covers the bag opening and the seam is located in the lower third of the tape.

The folder can be adjusted for tape widths from 1 31/32 to 2 3/4" (50 to 70 mm). Set the guides so, that the bag opening will be bound equally.

Tape Band

From Union Special manual PT1702-GR, page 32. The manual pages show the figures and reference letters.
Union Special manual PT1702-GR, page 32: Optional Tape Folder for BC211T11-1 & Ua
Manual page 32 — tap to enlarge
Need more help? Our technical team can advise on settings, parts and repairs. Call +44 (0)1706 871933 or send an enquiry.