Union Special 56100SABT2A bag making machine
Mechanical and technical information for styles 56100SABT2A, from Union Special manual PT1401SABT2A-GR: 24 topics on settings, threading, lubrication, maintenance and troubleshooting, each with the original manual pages.
Safety Rules
This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Oil Specification Requirements
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Torque Requirements
Torque specification given in the catalog are measured in inch-pounds or centimeter/kilograms. All straps and eccentrics must be tightened to 19-21 in. lbs. (22-24cm/ kg) unless otherwise noted.
All nuts, bolts, screws etc., without torque specifications must be secured as tightly as possible, unless otherwise noted. Special torque specifications of connecting rods, links, screws etc. are shown on part illustrations.
Threading and Oiling Diagram
For 401 stitch, thread machine as indicated above.
The looper threading has been enlarged for clarity.
The oil has been drained from the machine before shipping and the reservoir must be filled before starting to operate. Maintain oil level between the two red lines and add oil when oil level drops below the bottom red line. The machine is automatically lubricated and no oiling other than keeping the main reservoir filled is necessary. For further lubricating instructions refer to paragraph „LUBRICATION“.
Synchronizing Looper and Needle Motion
Synchronization is the most important adjustment involving the needle and looper motion relation, because it maintains the needle-looper relation at both the needle loop taking time, as well as when the needle enters the looper triangle. This adjustment ist best made using synchronization gauge set TT34.
Remove the throat plate, feed dog, looper and needle thread take-up wire, (also called strike-off wire) Fig. 3.
usinge gauge set TT34, re-attach the throat plate (A) to the throat plate support with the throat plate screws.
Insert the pin (B) into the hole for the looper and tighten with its screw. Turn the handwheel in operating direction (towards the operator), until the pin lightly touches the right edge of the throat plate. Insert the indiicator (C) into the hole for the needle thread take-up wire, and move it up or down until the pointer (D) on the indicator reads at „0“, and then tighten the screw. Now turn the handwheel in opposite of operating direction (away from the operator), until the pin again lightly touches the right edge of the plate.
If the machine is synchronized the pointer on the indicator should again read „0“, If the pointer is above or below the „0“ the machine is out of synchronization.
A variation of one line is allowable.
To synchronize the machine the following procedure should be followed. Thread screw (F) (99271), from gauge kit TT34, into the looper drive lever rocker shaft through the center of the thrust adjustment screw.
If the pointer (D) on the indicator reads above the „0“ (Fig. 3A), loosen screw (E) in the looper drive lever and pull screw (F) (99271), slightly towards the operator. Retighten screw (E) in the looper drive lever and recheck the synchronization as outlined above.
Repeat as necessary to obtain proper synchronization.
If pointer on the indicator reads below „0“, (Fig. 3B) loosen Fig. 3 screw (E) in the looper drive lever and tap screw (F), (99271), slightly away from the operator. Retighten screw (E) in the looper drive lever and recheck the synchronization as outlined above. Repeat as necessary to obtain proper synchronisation.
Synchronizing Looper and Needle Motion
CONTINUED) Fig. 3B If synchronization gauge set TT34 is not available, the following procedure can be used.
Turn handwheel in the operating direction until the point of the looper (A, Fig. 4) moving to the left, is even with the left side of the needle (B) . Note the height of the eye of the needle with respect to the looper point (see Fig. 4A) Turn the handwheel in the reverse direction until the point of the looper again moving to the left, is even with the left side of needle (see Fig. 4A). If the height of the eye of the needle with respect to the looper point are the same, looper and needle motions are synchronized - a variation of .005 inch (.15 mm) is allowable. It the distance from the eye of the needle to the point of the looper is greater when the handwheel is turned in the operating direction, the looper drive lever rocker shaft will have to be moved slightly towards the rear. Moving the shaft toward the front acts the reverse.
NOTE: The 1/64 inch (.4 mm ) dimension shown in Fig. 4A is for final setting of needle bar height.
Adjust looper drive rocker lever shaft as follows:
Loosen screw (C, Fig. 4) in looper drive lever (D). A rod of .146-40thd or Union Special Screw No. 992761 can be threaded into the looper drive lever rocker shaft through the center of thrust adjusting screw (E). Tap or pull slightly as required to position shaft for proper synchronization. Tighten screw (C) securely and remove rod or screw used to position shaft.
Fig. 4 Fig. 5 Loosen lock nut (F) and TORQUE thrust adjusting screw (E) to 6 in. lbs (7cm/kg), re-tighten lock nut (F) securely. With the looper at extreme right end of travel, check location of the right looper connecting rod bearing using gauge No. TT35. Place large hole of gauge over threaded stud (A. Fig. 5). The left end of gauge should locate against the RIGHT side of looper rocker cone (B). If adjustment is necessary, loosen clamp screw (C) and reposition looper drive lever (D) as required, then tighten screw (C).
If gauge is not available, check setting with a scale.
Distance between the centerline of rocker cone and centerline of looper drive lever stud should be 4 1/16 inch (103,2 mm) as shown in Fig. 5 when looper is at its extreme right end of travel.
Looper and Needle Setting Alignment of Needles
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Close Setting of the Looper to the Needles
When the handwheel is turned in sewing direction and the loopers (A, Fig. 9) move to the left, their tips have to be so adjusted that they touch the back of the needles (B, Fig. 9) evently without pushing them away. For adjustment losen screw (A, Fig. 9A) and move the looper holder (B, Fig. 9A) as required to the front or to the back. Tighten screw (A, Fig. 9A) again. Should the loopers not evenly touch the needles, losen one of the two screws (C, Fig. 9A) and push the corresponding looper tip towards the needle or away from the needle and tighten screw (C, Fig. 90A) again. If necessary, repeat the adjustment with the second looper.
Fig. 9 Fig. 9A
Threading
Draw looper and needle threads into the machine and start operating on a piece of fabric. Refer to threading diagram (Fig 1, Page 5) for manner of threading this machine.
Thread Tension
Tension on the needle thread should be only sufficient to produce uniform stitches on the under surface of the fabric. Tension on the looper thread should be just sufficient to steady the thread.
Thread Cast-off Wire and Needle Thread Guide Setting
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Special Instructions Needle Lever
When adjusting needle lever or replacing related parts, follow instructions sequence as listed:
1. Install „O“rings (A, Fig. 18) onto needle lever stud (B) and thrust collar (C).
2. With needle lever (D) in machine and positioned properly, insert stud (B) through hole in needle lever until its shoulder contacts the needle lever and the word „UP“ on stud is in the upright position. While making sure no binding exists in the needle bar link, secure stud (B) with the front set screw in top of machine bed.
3. Install temper load ring (E) and compression cups (F) onto stud (B), then push ring and cups through opening in machine bed.
4. Install thrust collar (C) onto stud (B) being careful not to damage „O“ ring. Compress components together by tightening screw (G) until washer (H) bottoms against stud (B). Secure stud (B) in position using the rear set screw in top of bed.
5. To check temper load ring for proper compression, remove screw (G) from stud (B) and loosen rear set screw in top of bed. Thrust collar (C) should spring out .003-.007 inch(.08-.18mm). Compress load ring in revers order, then tighten rear set screw.
6. With indented „UP“ on stud (B) in upright position, install bearing oiler (J) so its hook sets in oil supply hole (K) of stud. When hook and stud are secured in their proper positions, the proper amount of oil will be channeled to stud for lubricating needle lever (D).
Lubrication
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Looper Setting
Check the distance between middle of bearing assembly 29476LV at looper lever 56243K (A Fig. 6) and middle of rocker assembly 29192V (B Fig. 6). The distance has to be 4 1/16”(103.2 mm) ( ± 0,5 mm) (Fig. 6), when the looper lever (A Fig. 6) is in its right end position.
Insert a new needle, type and size specified. Looper gauge is 0.16 inch (4 mm - ± 0,2 mm) which is the distance from the front point of looper (A, Fig. 7) to centerline of the left needle (B) when looper is at extreme right end of its travel. Adjustment can be made by loosening nut (D), (it has a left hand thread) and nut (E); turn connecting rod (F) as required to attain specified dimension. Hold connecting rod in position and tighten nut (E), then nut (D).
NOTE: Be sure that the left ball joint is in a vertical position and does not bind after adjustment.
Needle Bar Height
Height of needle bar (A, Fig. 8) is correct when the top of the needle eye is even with the lower edge of the looper and the point of the looper is behind the needle and by 0.2 - 0.5 mm left of the needle (Fig. 8A).
Adjustment can be made by loosening screw (C, Fig.
8) and at the same time clamp the needle bar (A, Fig.
8) with a screwdriver (B, Fig. 8) and turn the needle bar connection (D, Fig. 8) accordingly up or down and retighten screw (A, Fig.8).
Check adjustment and repeat if necessary.
Fig, 8 Fig, 8A
Feed Dog Setting
Feed dog (A, Fig. 10) should be centered in throat plate (B) with equal clearance on all sides and ends with feed travel set to desired stitch length. At highest point of travel, tips of feed dog teeth should extend the depth of 3/64! above throat plate and parallel to same. Screw (C) should be set to support feed dog after screw (D) has been loosened which secures feed dog in position.
Parallel adjustment can be made by loosening nut (A.
Fig. 11) and turn screw (B) clockwise to lower front of feed dog, counterclockwise acts the reverse. When properly set, retighten nut (A).
Right to left adjustment can be made by loosening screws (F, Fig. 12 ) and slightly move feed rocker (G) on feed rocker shaft (H) as required, then retighten screw.
Check to ensure that feed rocker arm (J) does not bind after adjustment.
Forward or rearward centering of feed dog can be accomplished by loosening nuts (K. Fig. 12), move feed rocker (G) as required and retighten nuts.
Changing Stitch Length
Set the stitch to required length. This is accomplished by loosening lock nut (A, Fig. 12) 1/2 turn, (it has a left hand thread) on the end of the stitch regulating stud and turning stitch adjusting screw (B) located under the left end of the cloth plate in the head of the mainshaft (C), which is marked with „L“ and „S“. Turning the screw in a clockwise direction shortens the stitch (moves stitch regulator stud forward the „S“) and a counterclockwise direction lengthens the stitch (moves stitch regulator stud forward the „L“). Retighten the lock nut securely.
To prevent destructive damage to the feed drive bearing, key screw (D) must engage in „U“ shaped key slot in ferrule (E).
NOTE: Any change in stitch length will require a change in rear needle guard setting.
Rear Needle Guard
Set the rear needle guard (F, Fig. 13) so, that it touches the rear of the needle (B, Fig. 13). without pushing it away, when the looper (A, Fig. 13) in its movement runs from right to left and just starts to touch the needle with its tip. For adjustment losen screw (C, Fig. 13). The height of the needle guard (F, Fig. 13) has to be adjusted with the screw (D, Fig.13), so that the bottom edge of the bevel (E, Fig. 13) is in one line with the bottom edge of the needle eye. Tighten the screw (C , Fig. 13) again.
Check the setting when required.
NOTE: Any change in stitch length will require a change in rear needle guard setting.
Setting of the Upper Feed Dog
The upper feed dog is screwed on with screw (A, Fig.
14) to the guide as shown in picture.
Screw (B) with the lock nut (C) is used for height adjustment of the upper feed dog. It should be set so that between the feed dog teeth of both feed dogs a margin of 0,1 mm remains when upper feed dog is in its lowest position and lower feed dog in its upper position.
Both feed dogs should be horizontal when in motion.
Between the lever (D) and the upper feed dog there should be play of 0,2 to 0.4 mm when the upper feed is in its lowest position. Lever is used for lifting it.
Presser Bar Setting
Presser bar connection and guide 51257M have to be adjusted in such a way that when the presser foot rests on the throat plate there should be a distance of 1/16“ (1.6 mm ± 0.2 mm) between lower edge of the presser bar connection and guide housing (Fig.15).
Adjustment is made by turning handwheel to position needle bar at bottom of stroke. Loosen screw (F) and while holding presser foot down on throat plate, position presser bar connection and guide as required to attain specified clearance and retighten screw.
Presser Foot Pressure
Regulate the presser spring regulation screw (A. Fig.
17) so that it exerts only enough pressure on the presser foot to feed the work uniformly when a slight tension is placed to the fabric. Turning it clockwise increases the pressure, counterclockwise acts the reverse.
Troubleshooting: problems, causes and solutions
This topic is shown as the original manual page below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Machine Description
This topic is shown as the original manual pages below. Its text is not reproduced here because it could not be checked word for word against the printed manual (for example, English and German printed side by side, or values inside drawings).
Aligning Mainshaft to Crankshaft
As viewed looking down from rear of machine, spot screws (A, Fig. 19) in the couplings must align with the spots in the looper drive crank (B) and set screws (C) must align with the flats on crankshaft (D) and mainshaft (E).
Mainshaft must be positioned laterally with .060 inch (1.5mm) clearance between the right side of its head and the bed .060” (1.5 mm) casting as shown in Fig. 20.
Looper drive crank (B, Fig. 19) must be positioned laterally with 1/32 inch (.8mm) clearance between it and the mainshaft (E) as shown in Fig. 19. Once these setting are made, it is very important that the couplings are tightened in the following sequence for best performance.
Fig. 19 Tighten spot screws (A) temporarily, to the looper drive crank. Tighten set screws (C) temporarily to the crankshaft and mainshaft. Torque screws (F) to 19-21 in.lbs (22-24 cm/kg). Loosen spot screws (A) and set screws (C). Re-torque screws (F) to 19 - 21 in.lbs (22-24 cm/kg), then torque screws (A and C) to 19 - 21 in.lbs (22
- 24 cm/kg.
Fig. 21 The oil drip plate (A, Fig. 21) located in the oil reservoir should be positioned with its tip in the recessed cut out in the bed casting, as far to the left as possible without touching. It has elongated mounting holes and can be adjusted by loosening (2) screws (B) in top of the oil reservoir back cover to position as required.
TROUBLE SHOOTING: When sewing problems occur (malformed stitches) always change needle first!